Home page | news | supply and demand | downloading Today is:
Automation in line number according to increase in... In data increase...
Home page forum news
Current position:Home page >> news >> factory automation >> power source >> main text
In data increase......

One kind of new computer power source
Origin: Input time: 07-06-10 01:48:10English version

One kind of new computer power source
----JASUNY USPS introduction
JASUNY (outstanding is popular) USPS (uninterrupted switching power supply), also in called sets at type UPS (Internal UPS), it is the switching power supply and UPS which uses the present computer unifies in together, causes the computer power source simultaneously to have the UPS function.
JASUNY USPS uses the innate patent technical design, it sets at the UPS function in the switching power supply, has the essentially difference with the traditional UPS+SPS power supply. Its main characteristic displays in following four aspects:
In 1. power sources, AC inputs part of extensions to change into each group of DC, the supplies computer respectively uses electricity the load; Part of extensions change into DC which the battery needs, for battery charge. The battery took the reserve power source directly by DC to the computer power supply, this power supply way reduced the traditional UPS+SPS power supply pattern because AC to transfer DC, DC inverts AC, AC changes the energy which DC produced to lose (chart again one), enhanced the energy transfer efficiency.


According to this in new window browsing picture

The chart one outstanding is popular USPS and the traditional UPS+SPS power supply way contrast
2. when inputs AC to be lower than some as soon as supposes the localization value, the battery take compensates the power supply way to use electricity the energy as the computer which the load provides needs, guaranteed each group of DC outputs stably, chart two. This technology effectively has promoted the output voltage to the input voltage undulation compatibility, undulates in the big environment in the alternating voltage, avoids the AC undulation causing the disturbance which the UPS frequent cut brings, reliably guarantees the computer stable movement, simultaneously can the most effective economical battery energy.


According to this in new window browsing picture

The chart two outstanding is popular USPS and traditional UPS the DC&AC energy relations compares
3. JASUNY USPS also may use the double mains input, 1+1 redundant ways, are equal to redundancy UPS coordinate the redundancy again SPS, constitutes 22 mutually is the redundancy, thus enormously enhances the power supply system the reliability and 可用?(chart three), reduces the power supply system total cost, this extremely has the significance to the power supply sensitive equipment and the place.


According to this in new window browsing picture
Chart three redundancies USPS vs redundancy UPS
4. traditional computer power supply safeguards uses is the UPS centralism power supply protection, namely a set of UPS system to many computer equipment implementation protection, link appears the breakdown can affect after that all current collector. This kind of protection plan to UPS system request very strict, the earlier period invests in a big way, later period maintains the specification high, the cost is big, but USPS is the protective measures which uses breaks up the whole into parts, a realization most terminal pair of protection, may enormously reduce the influence which the power supply system breakdown produces, enormously reduces power supply system the simple point failure rate.

Synthesizes, JASUNY USPS has the following merit:
1, power source efficiency high, the present power supply pattern (UPS+SPS) needs to transform many times from AC to DC, each time transforms all has the energy loss, but JASUNY□USPS only has a time of transformation, therefore energy loss small, the overall effectiveness index is high, energy conservation rate 5%-20%. Effectively reduces the operating cost, economical consumes the electricity disbursement for the user.
2, because the secondary energy sources (battery) take compensates the power supply way to provide the energy as the computer, even if the AC undulation cannot cause the DC output undulation, thus to computer power supply stabler, the power source own reliability, 可用?is high.
3, the AC to DC transformation truly achieves "0" the switching time, moreover is the steady cut.
4, because the UPS function has poured into in the computer power source, the battery also may install in the computer outside, does not need to hang UPS, therefore has saved the extra space which UPS takes.
5, usually in has many computer run in the environment, uses the UPS centralism power supply protection, but once the UPS system appears the breakdown, this UPS system protects the computer suffers implicates, but JASUNY□USPS is a pair of terminal protection, a USPS breakdown only affects the computer which it protects, does not affect other computers, therefore the power source 可用?is high. If uses redundancy USPS, the power source reliability, 可用?is higher.
6, UPS needs the specialist to maintain, maintains the cost to be high, JASUNY□USPS does not need the specialist to maintain, maintains the cost greatly to reduce.
7, uses traditional UPS, either the big horse pulls the car to create the power supply system initial investment waste, later period operating cost waste; Either expands accommodates not conveniently, the increase newly allows 量必 to eliminate the old UPS equipment. Uses JASUNY□USPS completely does not have above problem, may achieve for the user appropriatelies, extremely facilitates expands accommodates.
8, JASUNY□USPS provides intelligent management software and the many kinds of communications connection, may realize the far-end network management; Provides AC to fall the electricity or the battery electricity pulls down the warning to prompt, as well as automatic memory, safe withdrawal, automatic pass machine operation.


Chief-editor: Article author:

In data increase......

Hot spot article
Intelligence electrical power distribution system
[ Prestige reaches electricity ] NOVA-E667 and the XP broadcast news, the weather forecast, the stock quotation, multimedia advertisement model application
Taiwan Province natural gas and regeneration energy electric power compulsory policy design
The electrical power system controls the seal lead-acid battery with the valve the maintenance
When - frequency analysis in automobile diagnosis application
Shallowly discussed installs in the electric power manostat the American JOSLYN thunder and lightning surge protector and the filter function (numerical control engine bed)
A design high performance 65W pair of road outputs 1/4 brick module power source the technical introduction
UPS technology, characteristic and development
The 35kV countryside electrical network optimizes the plan the research
County level electric power dispatch automated system anti-radar
In data increase......