Home page | news | supply and demand | downloading Today is:
Automation in line number according to increase in... In data increase...
Home page forum news
Current position:Home page >> news >> factory automation >> power source >> main text
In data increase......

Decides the voltage input, the constant voltage output
Origin: Input time: 07-06-10 01:48:21English version

The WDY series product is the isolation constant pressure input constant voltage output series, this kind of product has the efficiency high, the precision high, the stable performance is good and so on the characteristic. It is suitable for the digital signal processing electric circuit and the input voltage change not big analogous circuit, specially is suitable to requests a higher electric circuit and to the noise sensitive electric circuit to the voltage stability. When the input voltage range of variation surpasses ±10%, should use KW (width voltage input) the series product.

Yaohua WDY XXSXX-1W series general characteristic:
Insulation strength: 1000VDC short-circuits the protection: Has 
Dielectric resistance (note 1): 1000M Omega minimum value
Memory humidity: <= 95% 
Operating temperature: -40 ?~85 ?nbsp;coolant conditions: Nature 空冷 
Memory temperature: -40 ?~125 ?nbsp;
Sheathing material: Anti- burns the heat-resisting plastic 
Average non- fault time: >80 ten thousand hours
When work 温升: 30 ?maximum values, 20 ?typical values 

Yaohua WDY XXSXX-1W series input characteristic
Input voltage type 5V, 12V, 15V, 24VDC
The input voltage sufficiently permits the range of variation  Vin±5% (Vin±10%)
Biggest input voltage value (note 2) Vin+25%

Yaohua WDY XXSXX-1W series input level
Full load output 1W
Output voltage type  5V, 9V, 12V, 15VDC,
Output voltage accuracy . ±2%, (±1%)
Linear voltage regulation rate (note 3) 0.5% max
Load regulation rate 0.5% max
Temperature drifting coefficient 0.02%/ ?typical value
Ripple and noise (20MHz band width) 20mVp-pmax
Time full load efficiency 72% typical value (±5%) 68% typical value (±10%)

Note 1: Between the out-port and the outer covering in the ambient temperature 25 ? under the humidity 70% condition, adds time the 500VDC voltage obtains.
Note 2: The input voltage surpasses this value possibly to be able to create the damage which the permanence cannot be restored.
Note 3: Under full load condition in input voltage ±10% range of variation, output voltage along with input voltage rate of change
Note 4: Besides specially indicates, all data all are in the ambient temperature 25 ?tests obtained.

Chief-editor: Article author:

In data increase......

Hot spot article
The electrical power system controls the seal lead-acid battery with the valve the maintenance
Partition control terminal
110 kV electrical network computer 整定 calculates the new plan
The 4-20mA signal isolation, changes delivers and two systems return routes output way application
The emergency lighting counts a worth noting question
Has fast short-circuits the protection 1,140 volts 90 kilowatt intermediate frequencies power source
Can discuss the wall hanging power source prospects for development
UPS technology, characteristic and development
Computer technology in correspondence voltage-stabilized source application
South Jiangyin ?LZ8-400 直进?drawing machine
In data increase......
Website map
Copyright 2006-2008