RS-232 signal ultra long distance communication solution
Origin: Input time: 07-06-10 01:35:14English version


1: Solution synopsis:
The serial communication interface standard after the use and the development, at present already had several kinds. But all is the process changes in the RS-232 standard foundation then forms. Therefore, primarily discusses by RS-232C. The correspondence agreement together which the RS-323C standard is American EIA (the electronics industry federation) which with company and so on BELL develops in 1969 announces. It suits to the data transmission speed in 0 ~ 20000b/s scope correspondence. This standard to the serial communication connection related question, like the holding wire function, the electric appliance characteristic all did had explicitly stipulated. Because the general equipment merchant all produces and the RS-232C service pattern compatible communication facility, therefore, it takes one kind of standard, at present already in microcomputer correspondence connection widespread use.
In AT machine and after, does not support the 20mA electric current link connection, uses the DB-9 coupling, the achievement provides on the multi-purpose I/O card or the motherboard COM1 and the COM2 two serial interfaces couplings. It only provides the asynchronous communication 9 signals. The DB-25 coupling pin assignment and the DB-25 pin signal is completely different. Therefore, if with matches meets DB-25 the coupling the DCE equipment connection, must use the special electric cable line.
Electric cable length: Is lower than 20kb/s when the correspondence speed, the RS-232C direct connection maximum physical distance is 15m (50 feet). The maximum direct transmission distance explained that, RS-232C standing operating procedure, if does not use MODEM, is smaller than in 4% situation in the element distortion, between DTE and DCE the maximum transmitting range is 15m (50 feet). Obviously this maximum distance is smaller than under 4% premise in the element distortion to produce. In order to guarantee the element distortion is smaller than 4% request, the interface standard stipulated in the electrical specification, the driver load electric capacity should be smaller than 2500pF.
Because the RS-232 standard appears time comparison early, although this kind of standard now still generally applied in the industrial automation, places the monitoring, the data acquisition, and so on many domains, but its congenital flaw also extremely was actually obvious, that was its electrical standard limit, caused the RS-232 signal not to be able to carry on the long distance the communication, moreover a flaw was the RS-232 connection very easily because of factor and so on surge, return route voltage, the merely 10 several volts voltages undulations, possibly caused the connection chip the damage. Based on this present situation, the domestic and foreign very many companies all develop RS-232 the photoelectricity isolation long-line driver, this kind of product can satisfy RS-232 in 1,000 meter about signal entire duplex point-to-point (Point to Point) the communication, moreover beginnings and ends mutually photoelectricity isolation.
But this kind of plan also has not not perfectly place, that is by the twisted pair line took under the transmission line cable medium condition, is unable to complete the long-distance range communication, the long-distance range communication, only can depend on the expensive optical fiber communication to solve this need, but this plan obviously has the wiring to be expensive, interface equipment usual price also quite high question.
The our company according to the customer the demand, now provided RS-232 in to the twisted pair line to take the communication medium, under the half-duplex communication, the low gear rate pattern, was allowed to transmit the RS-232 signal 10 kilometer within the solution, product is called RS-232 Short Haul Modem. This plan not only may solve the RS-232 point-to-point communication, moreover also may compose has the pitch point the main line system structure, this communication way and usual RS-485 main line similar, each hangs in the network has RS-232 Short Haul Modem the RS-232 interface equipment, even hangs meets the RS-485 Short Haul Modem RS-485 equipment which the our company produces, may control the computer with on host the way communication which to the wheel inquires.
In order to guarantee the network the security, the our company provides RS-232 Short Haul Modem is the industry level standard design, not merely is the signal photoelectricity isolation, moreover the power source also is the DC-DC isolation transforms, and has anti- is struck by lightning the primary device to use to make 突波 the protection. The our company produces RS-232 Short Haul Modem and RS-485 Short Haul Modem, its core principle is transforms into RS-232 perhaps the RS-485 level CAN (Controller Area Network) the main line level, far-end RS-232 Short Haul Modem and RS-485 Short Haul Modem, again transforms into the RS-232 level or the RS-485 level by the CAN level, thus has completed RS-232 perhaps the RS-485 signal ultra long-distance transmission. Because well known, the CAN main line has the prominent reliability, timeliness and the flexibility. The CAN main line passes CAN controller connection chip 82C250 two out-ports CANH and CANL and the physical main line is connected, but the CANH end condition only can be the high level or the suspended state, the CANL end only can be the low level or the suspended state. This guarantee cannot leave the phenomenon in the RS-485 network, when the system has the mistake, when appears at the same time the multi- pitch points to the main line transmission data, causes the main line to present short-circuits, thus damages certain pitch points the phenomenon. Moreover the CAN pitch point has the automatic shut-off output function in the wrong serious situation, causes on the main line other pitch points operations not to receive affects, thus guaranteed cannot leave the phenomenon in the network, because the individual pitch point has the problem, causes the main line to be at "the deadbolt lock" the condition. Therefore selects this method to solve the RS-232/485 ultra long-distance range communication, does not lose is one kind stable, is reliable moreover the economical solution. In in the RS-232 very-long-range solution, stable is reliable as a result of its product performance, has been massively used by the domestic war industry unit, displays splendidly in the practical application.
______________________________________________
--------------------------------
Jinan Pu news science and technology limited liability company
Sale department: Li Min
Telephone: 0531-846424518 86.652206 million
Facsimile: 0531-86424519
Electricity postal: Limin@pxtech.cn
Websitewww.pxtech.cn

Jinan Puxun Technologies.Co., Ltd
No.5-1 Yangtouyu Street Jinan Shandong Province.P.R.China
Sales Manager: Mr.Li Min
Tel:+86-531-86424518 86.652206 million
Fax:+86-531-86424519
E-mail: Limin@pxtech.cn
MSN:puxuntech@hotmail.com
Skype:pxtech2
Web:www.linkports.com

According to this in new window browsing picture
Chief-editor: Article author:

In data increase......

Hot spot article
The association labor controls the scheme to restore the function according to
Walks 向点 interlocks to --- from PCI, PCI-X to PCI-Express
Dynamic IP in network configuration dying machine
Multimedia synthesis self-service service terminal solution
PCM-5330 in postal service profession application
Howlets the Windows2000 system large capacity hard disk (120G, 200G)
Grinds raises the P4 long card in the petroleum profession application
Any is PC104
The hard disk wrongly causes the system is unable normally to install
Continual ingredient automatic control system
In data increase......
Website map
Copyright 2006-2008