Home page | news | supply and demand | downloading Today is:
Automation in line number according to increase in... In data increase...
Home page forum news
Current position:Home page >> news >> enterprise news >> application case >> main text
In data increase......

Conductivity survey principle
Origin: Input time: 07-05-10 12:40:38English version


Electrode

    Causes the ion in to measure in the solution the movement electric field is by produces with the solution direct contact two electrodes. This must the material which corrodes by the anti- chemistry make to the potential electrode. Actual center after the material which commonly used arrives has the titanium and so on. The potential electrode is composed which by two electrodes was called 为尔 the fatigue executes (Kohlrausch) the electrode.

    The conductivity survey needs to clarify two aspects. Is the solution electric conductance, another is in the solution the 1/A geometry relations, the electric conductance may through the electric current, the voltage survey obtain. This survey principle in now directly demonstrated in the measuring instrument obtains the application.

    

But  K= L 

 A - potential electrode effective pole plate

 L - two pole plates distances
    This value is called the electrode constant. Has the uniform electric field in the electrode between in the situation, the electrode constant may pass 

    Crosses the geometry size to figure out. When two area are the 1cm2 square shape pole plates, when between is separated by 1 cm composition electrode, this electrode constant K=1cm-1. If obtains electric conductance value G=1000 mu S with this to the electrode, then is measured the solution conductivity K=1000 mu S/ cm.

    In ordinary circumstances, electrode often shaping unit non- uniform electric field. This time, the electrode constant must use the standard solution to carry on the determination. The standard solution generally all uses KCl solution this is because in the KCl conductivity different temperature and the density situation is extremely stable, accurate. 0.1 mol/l KCl solution in 25 ?time conductivity is 12.88mS/CM.

     The so-called non- uniform electric field (also is called as stray field, 漏泄 field) does not have the constant, but is concerns with the ion type with the density. Therefore, a pure stray field electrode is the most too bad electrode, it cannot satisfy the width through a calibration the survey scope need. `

Information origin: China industrial equipment net
Chief-editor: Article author:

In data increase......

Hot spot article
Branch beginning construction industry switchboard in some power plant DCS system application
Petrification production data gathering system
Four industries ethernets protocol analysis
Frequency changer frequency hypothesis several methods
SOAP in industry control and automated domain application
Field bus type and standard
Reaches PLC to deliver after the system in the towel loom the application
KEB F4 typical wiring diagram
Programmable controller installment and maintenance
Coal mine video frequency monitoring plan
In data increase......
Website map
Copyright 2006-2008